What this calculator does
Coal still generates about a third of the world’s electricity, and most questions about a coal plant reduce to the same chain of numbers: how many megawatt-hours it sends out, how much coal that takes, and what comes out of the stack and the ash pond. This calculator works through that chain for any plant. You enter the net capacity, capacity factor, efficiency and coal quality; it returns coal per hour, per day and per year, the CO₂, ash and SO₂ that go with it, and the short-run cost of each MWh with and without a carbon price.
The formula
Heat input per MWh (GJ) = 3.6 ÷ net efficiency Coal per MWh (t) = heat input ÷ net calorific value (GJ/t) CO₂ per MWh (t) = heat input × emission factor (kg/GJ) ÷ 1,000
SO₂ (t) = coal × sulphur fraction × 2 × (1 − FGD removal) Ash (t) = coal × ash fraction
Short-run cost per MWh = coal per MWh × coal price + CO₂ per MWh × carbon price + variable O&M
The factor of 2 in the SO₂ line comes from molecular masses: each 32 kg of sulphur becomes 64 kg of SO₂. The calorific values and CO₂ factors are the IPCC 2006 defaults for each coal rank (25.8 GJ/t and 94.6 kg CO₂/GJ for bituminous coal, 11.9 GJ/t and 101 kg/GJ for lignite).
Worked example
The defaults describe a 600 MW supercritical unit at 39% net efficiency and 60% capacity factor, burning bituminous coal with a net calorific value of 25.8 GJ/t delivered at 110 per tonne.
- Generation: 600 × 8,760 × 0.60 = 3.15 TWh a year.
- Heat input: 3.6 ÷ 0.39 = 9.23 GJ per MWh.
- Coal: 9.23 ÷ 25.8 = 0.358 t per MWh, so about 1.13 million tonnes a year or 3,100 t a day. At full load the mills grind 215 t an hour.
- CO₂: 9.23 × 94.6 = 873 kg per MWh, 2.75 Mt a year.
- Ash at 12%: about 135,000 t a year. SO₂ at 0.8% sulphur and 95% FGD removal: about 900 t a year (18,000 t without scrubbers).
- Cost: 0.358 × 110 = €39.4/MWh of fuel, plus €4 variable O&M, so €43.4/MWh before carbon.
Set the carbon price to 80 €/t and the carbon cost jumps to €70/MWh, more than the coal itself. That is the arithmetic that pushed coal off the merit order in much of Europe after 2021.
Why coal quality matters so much
The coal rank changes the tonnage more than any other input. Swap the bituminous coal for lignite at 11.9 GJ/t and the same 600 MW plant needs more than twice the tonnage, about 2.4 million tonnes a year, and emits slightly more CO₂ per GJ. That is why lignite plants are built at the mine mouth: moving a low-energy, wet fuel any distance makes no sense. Seaborne coal is traded on a heating-value basis, typically 6,000 kcal/kg NAR (net as received, about 25.1 GJ/t) for Newcastle and Richards Bay benchmarks, or 3,800–4,200 kcal/kg for Indonesian sub-bituminous grades. Multiply kcal/kg by 0.004187 to get GJ/t.
Coal analyses are also quoted on different bases: as received, air dried, dry, or dry ash-free. The calculator needs the as-received net value, since that is what actually goes into the boiler with its moisture.
Typical values
| Plant type | Net efficiency (LHV) | Coal per MWh (bituminous) | CO₂ per MWh |
|---|---|---|---|
| Old small subcritical | 28–32% | 0.44–0.50 t | 1,050–1,200 kg |
| Subcritical, 300–600 MW | 33–37% | 0.38–0.42 t | 920–1,030 kg |
| Supercritical | 38–41% | 0.34–0.37 t | 830–900 kg |
| Ultra-supercritical | 42–46% | 0.30–0.33 t | 740–810 kg |
| Lignite (modern supercritical) | 40–43% | 0.75–0.85 t of lignite | 850–1,000 kg |
How to read the results
- Coal burned per year is the headline for supply contracts, rail and port logistics.
- Coal per MWh and CO₂ intensity are the per-unit numbers to compare with other plants. For a gas comparison use the heat rate calculator.
- Gross capacity shows the generator output before the plant’s own consumption. Mills, fans, pumps and flue gas desulphurisation typically take 6–10% of gross output.
- The cost chart stacks fuel, carbon and variable O&M. This is the short-run marginal cost that sets the plant’s place in the merit order, not its full cost; for that, use the LCOE calculator.
Limitations
Efficiency is treated as constant. Real plants lose two to four percentage points at low load and during starts, and cycling coal units now spend much of their time there. Calorific value, ash and sulphur vary from shipment to shipment. NOₓ, mercury and particulates depend on control equipment and are not modelled. CO₂ covers combustion only; methane from mining and transport emissions would add roughly 5–15% on a lifecycle basis. To price carbon on any fuel mix, see the carbon tax calculator.
Method & assumptions
Fuel heat input per MWh = 3.6 GJ ÷ net efficiency. Coal per MWh = heat input ÷ net calorific value (as received). Annual coal = coal per MWh × MW × 8,760 × capacity factor. CO₂ = heat input × emission factor (kg/GJ). SO₂ = coal × sulphur × 2 (molecular mass ratio) × (1 − FGD removal). Ash = coal × ash content. Short-run marginal cost = fuel + carbon + variable O&M per MWh.
Frequently asked questions
How much coal does a 1,000 MW power plant use per year?
How much coal is needed to produce 1 MWh of electricity?
How much CO₂ does a coal power plant emit per MWh?
What is the efficiency of a coal power plant?
How many trains of coal does a power station need?
What does it cost to generate electricity from coal?