Power plants & fossil calculator

Power plant heat rate calculator: efficiency, Btu/kWh and fuel per MWh

Convert between thermal efficiency and heat rate (Btu/kWh, kJ/kWh, kcal/kWh, GJ/MWh) on an LHV or HHV basis, then see how much coal, gas, oil or biomass a plant burns per MWh and per year, what the fuel costs and how much CO₂ it emits.

Editable share link Branded PDF report Free · no sign-up

Results

A net efficiency of 55% (LHV) equals a heat rate of 6,874 Btu/kWh HHV or 6,545 kJ/kWh LHV. Each MWh needs 6.55 GJ of fuel, about 190 m³ (Natural gas), costing 52.4 € and emitting 0.367 t CO₂.
Heat rate (HHV)
6,874Btu/kWh
6,204 Btu/kWh on an LHV basis
Net efficiency (LHV)
55%
Net efficiency (HHV)
49.6%
Heat rate (LHV)
6,545kJ/kWh
1,563 kcal/kWh
Fuel energy per MWh (LHV)
6.55GJ/MWh
6.87 MMBtu/MWh HHV
Fuel per MWh (Natural gas)
190m³
Fuel cost per MWh
52.4€/MWh
CO₂ per MWh
0.367t
367 g/kWh
Annual generation
1,927GWh
Annual fuel use
365.6million m³
12.61 PJ of fuel
Annual fuel + carbon cost
101million €
Annual CO₂
0.71Mt
Heat rate vs efficiency (LHV)
Typical net efficiency by technology (LHV)

Heat rate in every unit

UnitLHV basisHHV basis
Btu/kWh6,2046,874
kJ/kWh6,5457,252
kcal/kWh1,5631,732
GJ/MWh6.5457.252
MMBtu/MWh6.2046.874

Typical technologies

TechnologyEfficiency (LHV)Heat rate (kJ/kWh, LHV)Heat rate (Btu/kWh, LHV)
Old subcritical coal33%10,90910,340
Supercritical coal39%9,2318,749
Ultra-supercritical coal44%8,1827,755
Lignite (modern)40%9,0008,530
Gas engine / recip44%8,1827,755
Aeroderivative OCGT40%9,0008,530
Heavy-duty OCGT37%9,7309,222
CCGT (F-class)57%6,3165,986
CCGT (H/J-class)62%5,8065,503
Oil steam plant36%10,0009,478
Diesel genset38%9,4748,979
Biomass steam30%12,00011,374
Nuclear LWR33%10,90910,340
  • Heat rate = 3,600 kJ/kWh ÷ efficiency = 3,412 Btu/kWh ÷ efficiency. HHV/LHV conversion uses typical fuel ratios (gas 1.108, bituminous coal 1.045, lignite 1.09, oil 1.06).
  • Fuel calorific values and CO₂ factors are IPCC 2006 defaults; your fuel analysis will differ, especially for coal and lignite.

What heat rate tells you

Heat rate is the number power-plant engineers use instead of efficiency. It answers a practical question: how much fuel energy goes in for every kWh that leaves the plant fence? A plant with a heat rate of 7,000 Btu/kWh burns 7,000 Btu of fuel per kWh sent out. Because one kWh is 3,412 Btu, that plant turns 48.7% of its fuel into electricity and loses the rest as heat to the condenser, cooling tower and stack.

The two numbers carry the same information, but heat rate is easier to use for fuel accounting. Multiply it by generation and you have fuel burn; multiply by the fuel price and you have fuel cost per MWh. That is why traders talk about “spark spreads” and “dark spreads” computed from heat rate, and why utilities report heat rates to regulators.

This calculator converts in both directions, between five units, and on either heating-value basis. It then turns the result into physical fuel, cost and CO₂ for a plant of the size and capacity factor you enter.

The formula

Efficiency η = 3,600 ÷ HR (kJ/kWh) = 3,412.14 ÷ HR (Btu/kWh) = 860 ÷ HR (kcal/kWh)

η_HHV = η_LHV ÷ (HHV / LHV)

Fuel per MWh = HR (GJ/MWh, LHV) ÷ net calorific value CO₂ per MWh = HR (GJ/MWh, LHV) × emission factor (kg CO₂/GJ) Fuel cost = HR (GJ/MWh, LHV) × fuel price (per GJ)

The HHV/LHV ratios used are 1.108 for natural gas, 1.045 for bituminous coal, 1.06 for sub-bituminous coal and heavy fuel oil, and 1.09 for lignite and wood. Calorific values and emission factors are the IPCC 2006 defaults: 56.1 kg CO₂/GJ for gas, 94.6 for bituminous coal and 101 for lignite.

LHV or HHV: the trap in every comparison

The same gas turbine can be advertised at 41% efficiency in a European brochure and 37% in a US filing, and both figures are correct. The difference is the heating value. The higher heating value (HHV, gross) counts the latent heat of the water vapour formed in combustion; the lower heating value (LHV, net) does not. Power plants release that vapour through the stack, so LHV is the fairer measure of what the machine can do, and it is the IEA and European convention. The US EIA and most US utilities report HHV heat rates.

For natural gas, which contains a lot of hydrogen, the gap is large: an LHV efficiency of 55% is only 49.6% on an HHV basis. For coal the gap is small. Always check the basis before comparing two plants or two countries.

Worked example

The defaults describe a 400 MW combined-cycle gas plant at 55% net efficiency (LHV), running at a 55% capacity factor with gas at €8/GJ.

  • Heat rate (LHV) = 3,600 ÷ 0.55 = 6,545 kJ/kWh, or 6,204 Btu/kWh.
  • On an HHV basis efficiency falls to 55 ÷ 1.108 = 49.6%, and the heat rate becomes 6,874 Btu/kWh HHV.
  • Each MWh needs 6.55 GJ of gas, about 190 m³ at 34.5 MJ/m³.
  • Fuel cost is 6.55 × 8 = €52.4/MWh; CO₂ is 6.55 × 56.1 = 367 kg/MWh.
  • Over a year the plant sends out 1,927 GWh, burns about 366 million m³ of gas (12.6 PJ) and emits 0.71 Mt of CO₂.

Change the fuel to sub-bituminous coal and enter a US-style 10,000 Btu/kWh HHV heat rate (one of the presets), and you get a 34% HHV (36% LHV) plant that needs about 0.53 t of coal and emits about 0.96 t CO₂ for every MWh.

Typical heat rates

Technology Net efficiency (LHV) Heat rate (kJ/kWh, LHV) Approx. Btu/kWh (HHV)
CCGT, H/J-class, new 60–63% 5,700–6,000 6,000–6,300
CCGT, F-class 55–58% 6,200–6,550 6,500–6,900
Aeroderivative gas turbine 38–42% 8,600–9,500 9,000–10,000
Heavy-duty open-cycle GT 34–38% 9,500–10,600 10,000–11,200
Ultra-supercritical coal 42–45% 8,000–8,600 8,000–8,500
Subcritical coal (older) 31–36% 10,000–11,600 9,800–11,500
Nuclear light-water reactor 32–34% 10,600–11,200 ≈ 10,400 (EIA convention)

Fleet averages are higher than the best values because plants run at part load, start and stop, and age. EIA’s annual heat-rate table is a good reality check for US plants.

How to read the results

  • Heat rate (HHV) is the headline for US readers; the LHV figure in the hint and table suits IEA or European data.
  • Fuel per MWh is the physical quantity a fuel buyer cares about: cubic metres of gas or kilograms of coal.
  • Fuel cost per MWh is the short-run marginal cost of the plant before variable O&M and carbon. Compare it with power prices to see whether the plant is in the money.
  • CO₂ per MWh follows directly from heat rate and fuel. Better efficiency is the only way to reduce it without changing fuel or capturing carbon.

Limitations

Heat rate changes with load, ambient temperature, cooling-water temperature and plant age. A single number is an average. Calorific values and CO₂ factors are IPCC defaults; coal in particular varies widely, so use your own fuel analysis where you can. For full plant economics use the LCOE calculator, for coal-specific tonnages the coal power plant calculator, and for gas turbines at part load the gas turbine fuel consumption calculator.

Method & assumptions

Efficiency η = 3,600 ÷ heat rate (kJ/kWh) = 3,412.14 ÷ heat rate (Btu/kWh). LHV and HHV efficiencies differ by the fuel's HHV/LHV ratio: ηHHV = ηLHV ÷ (HHV/LHV). Fuel per MWh = heat rate (GJ/MWh, LHV) ÷ net calorific value. CO₂ per MWh = GJ/MWh × emission factor (kg CO₂/GJ, IPCC 2006). Annual figures = net MW × 8,760 h × capacity factor.

Frequently asked questions

What is the heat rate of a power plant?
Heat rate is the amount of fuel energy a plant burns to produce one kWh of electricity, usually given in Btu/kWh or kJ/kWh. It is the inverse of efficiency: a plant with a heat rate of 7,000 Btu/kWh converts 3,412 ÷ 7,000 = 48.7% of the fuel energy into electricity. Lower is better.
How do you convert heat rate to efficiency?
Divide 3,412 by the heat rate in Btu/kWh, or 3,600 by the heat rate in kJ/kWh. For example 10,000 Btu/kWh = 34.1% and 6,500 kJ/kWh = 55.4%. Make sure you know whether the figure is on a higher (HHV) or lower (LHV) heating value basis, because the same plant shows two different numbers.
What is the difference between HHV and LHV heat rate?
The higher heating value includes the energy released when water vapour in the flue gas condenses; the lower heating value does not. Power plants almost never recover that latent heat, so European and IEA statistics use LHV, while US EIA data uses HHV. For natural gas the HHV figure is about 10.8% higher than the LHV figure, for bituminous coal about 4–5% higher.
What is a good heat rate for a combined-cycle gas plant?
Modern H- and J-class combined-cycle plants reach 60–63% LHV efficiency at full load, which is about 5,700–6,000 kJ/kWh (LHV) or roughly 6,000–6,300 Btu/kWh HHV. The average US gas combined-cycle fleet runs at around 7,500 Btu/kWh HHV because of older units, part-load operation and starts.
What is the heat rate of a coal power plant?
Older subcritical coal units typically run at 9,500–11,000 Btu/kWh HHV (31–36% efficiency). Supercritical units reach about 8,700–9,200 Btu/kWh, and the best ultra-supercritical plants around 8,000 Btu/kWh, which is 42–45% LHV.
How much fuel does a power plant burn per MWh?
Divide the heat rate in GJ/MWh by the fuel's calorific value. A 55% efficient gas plant needs 6.55 GJ per MWh, about 190 m³ of natural gas. A 38% efficient coal plant needs 9.5 GJ, which is roughly 370 kg of bituminous coal at 25.8 GJ/t.

Sources & references

  1. US EIA — Average operating heat rate for selected energy sources (Electric Power Annual, table 8.1)
  2. IPCC 2006 Guidelines for National GHG Inventories, Vol. 2 Energy, ch. 1 (calorific values and CO₂ factors)
  3. IEA — Energy Statistics Manual (gross and net calorific values)
  4. IPCC AR5 WGIII Annex III — Technology-specific cost and performance parameters

Embed this calculator

Free for blogs, installers, schools and NGOs. Copy the code below; it updates itself automatically.