How this calculator works
A nuclear reactor is a heat source like any other thermal plant, but its fuel is counted differently. Instead of a calorific value per tonne, nuclear fuel has a burnup: the thermal energy, in megawatt-days, extracted from each kilogram of uranium before the fuel leaves the core. Once you know a reactor’s thermal output, its capacity factor and the burnup its fuel reaches, the yearly fuel requirement follows directly.
The calculator then works back up the fuel cycle. Enriched fuel needs a larger mass of natural uranium as feed and an amount of enrichment work measured in separative work units (SWU). Natural uranium is bought as U₃O₈ and converted to UF₆ before enrichment. Prices for each step give the front-end fuel cost per MWh.
The formula
Natural feed F = P × (x_p − x_t) ÷ (x_f − x_t) x_f = 0.711 % Tails T = F − P SWU = P·V(x_p) + T·V(x_t) − F·V(x_f) V(x) = (2x − 1) · ln(x ÷ (1 − x))
U₃O₈ (kg) = F × 1.1792 1 kg = 2.2046 lb
The value function V(x) is the standard way to measure enrichment work, independent of the technology (centrifuges today, gaseous diffusion historically). For a natural-uranium reactor such as CANDU, no enrichment is needed and feed equals the fuel loaded.
Worked example
The defaults describe a 1,000 MWe PWR with 33% net efficiency, a 90% capacity factor and fuel enriched to 4.4% U-235 that reaches 45 MWd/kgU, with 0.25% tails.
- Thermal power: 1,000 ÷ 0.33 = 3,030 MWt.
- Thermal energy: 3,030 × 365 × 0.90 = 995,500 MWd a year.
- Fuel loaded: 995,500 ÷ 45 = 22.1 tU, about 48 assemblies of 460 kg.
- Feed: 22.1 × (4.4 − 0.25) ÷ (0.711 − 0.25) = 199 tU of natural uranium, or 235 t of U₃O₈ (0.52 million lb).
- Separative work: 6.66 SWU per kg of product, so 147,000 SWU a year.
- With U₃O₈ at 80/lb, conversion at 60/kgU, enrichment at 170/SWU, fabrication at 350/kgU and a 1/MWh back-end fee, the fuel costs about 94 million a year, or 11.9 per MWh.
The same 7.9 TWh would take about 2.9 million tonnes of coal in a 38% efficient plant, or about a million tonnes of LNG in a modern combined-cycle plant.
What drives fuel use
Burnup is the main lever. Raising burnup from 33 to 50 MWd/kgU, as the industry did between the 1980s and today, cuts the fuel loaded and spent fuel discharged per year by a third. It needs higher enrichment, though, so natural-uranium needs fall much less. Efficiency matters too. A Gen III+ reactor at 36–37% net efficiency needs about 10% less fuel per MWh than an older unit at 33%. The tails assay is an economic choice: with cheap SWU and expensive uranium, enrichers strip tails down to 0.20% or lower and save feed. The uranium enrichment calculator finds the optimum.
Typical values
| Reactor | Enrichment | Burnup (MWd/kgU) | Fuel per year per 1,000 MWe |
|---|---|---|---|
| PWR, current fuel | 4.0–4.95% | 45–60 | 18–25 tU |
| BWR | 3.8–4.5% | 40–55 | 20–27 tU |
| VVER-1000 | 4.0–4.9% | 45–55 | 20–25 tU |
| PHWR / CANDU | 0.711% (natural) | 7–8 | 130–150 tU |
| HTGR (pebble bed) | 8–17% | 80–160 | 8–12 tU |
How to read the results
- Fuel loaded per year is the mass of fresh fuel the reactor takes in, and also the mass of spent fuel it discharges.
- Natural uranium is what has to be mined. Compare it with world production of about 50,000–60,000 tU a year to see why a reactor fleet’s needs are modest in tonnage.
- Separative work shows how much enrichment capacity the reactor occupies.
- Fuel cost per MWh is the front end plus the waste fee you entered. Fuel is a small share of nuclear generating cost; capital dominates. For the whole picture use the LCOE calculator.
Limitations
This is an equilibrium-cycle estimate. Initial cores, cycle-length changes, power uprates and outages change real reloads from year to year. Process losses in conversion and fabrication (about 0.5% each) and the enrichment of reprocessed uranium or MOX are not modelled. Uranium, conversion and SWU prices move with long-term contracts and spot markets; treat the defaults as illustrative.
Method & assumptions
Thermal power = MWe ÷ efficiency. Thermal energy per year (MWd) = MWt × 365 × capacity factor. Enriched uranium per year = MWd ÷ burnup (MWd/kgU). Natural-uranium feed F = P × (xp − xt) ÷ (xf − xt) with xf = 0.711%. Separative work = P·V(xp) + T·V(xt) − F·V(xf), V(x) = (2x − 1) ln(x / (1 − x)). U₃O₈ = U × 1.1792; 1 kg = 2.2046 lb.
Frequently asked questions
How much uranium does a 1,000 MW nuclear reactor use per year?
What is nuclear fuel burnup?
How much electricity does 1 kg of uranium produce?
What does nuclear fuel cost per MWh?
How many fuel assemblies does a reactor replace each refuelling?
How much nuclear waste does a reactor produce?
Sources & references
- World Nuclear Association — The Nuclear Fuel Cycle and Uranium Enrichment
- World Nuclear Association — Economics of Nuclear Power (fuel cost breakdown)
- IAEA — Nuclear Fuel Cycle Information System and Power Reactor Information System (PRIS)
- OECD NEA / IAEA — Uranium 2022: Resources, Production and Demand (Red Book)
Embed this calculator
Free for blogs, installers, schools and NGOs. Copy the code below; it updates itself automatically.