When you light a gas hob, the flame burns methane that may have left a rock formation two or three kilometres underground a few days or weeks earlier, possibly in another country. In between it was cleaned, compressed, piped hundreds or thousands of kilometres, perhaps stored in a salt cavern, then stepped down through several pressure levels before reaching your meter. The world consumed about 4,100 billion cubic metres of gas in 2024, according to the Energy Institute Statistical Review. Here is how it gets from the well to the stove.
Where the gas comes from
Natural gas forms alongside oil from organic matter buried and cooked over millions of years. It sits in porous rock under an impermeable cap. Some fields hold mostly gas (“non-associated gas”); in others, gas comes up with oil (“associated gas”). Shale and tight gas is trapped in rock so dense that it must be fractured to flow, covered in shale and fracking explained.
Raw gas is mostly methane, but rarely pure. Depending on the field it can contain:
- Natural gas liquids (NGLs): ethane, propane, butane and heavier condensate.
- Water vapour and sometimes free water.
- CO₂, from a fraction of a percent to over 50% in some Southeast Asian fields.
- Hydrogen sulphide (H₂S), which is toxic and corrosive. Gas with it is called “sour”.
- Nitrogen, helium and traces of mercury.
Processing: making gas pipeline-ready
Before gas can go into a long-distance pipeline it must meet a quality specification, usually a set heating value, a maximum water content and strict limits on H₂S and CO₂. A gas processing plant does this in stages:
- Separation of liquids and condensate at the wellhead or in a central facility.
- Acid gas removal, normally by bubbling gas through an amine solution that absorbs H₂S and CO₂.
- Dehydration with glycol or molecular sieves, so water does not form ice-like hydrates in cold pipes.
- NGL recovery, chilling the gas to condense ethane, propane and butane, which are sold to petrochemical plants or as LPG.
In Malaysia, gas from offshore Terengganu is processed at PETRONAS Gas plants in Kertih and Santong before entering the Peninsular Gas Utilisation (PGU) system, a trunk network of more than 2,500 km that carries gas to power stations, industry and cities along the peninsula and into Singapore.
Transmission: the gas motorway
Clean gas moves through large steel pipelines, often 600 to 1,400 mm in diameter, at pressures of about 40 to 100 bar. Friction gradually reduces pressure, so compressor stations are spaced roughly every 100 to 200 km. Many burn a little of the gas itself to drive their turbines, which is why transmission uses a few percent of the gas it moves on very long routes.
The scale is large. The United States has about 300,000 miles (roughly 480,000 km) of interstate and intrastate transmission pipeline, and over 2 million miles of distribution mains and service lines, according to the Pipeline and Hazardous Materials Safety Administration. Russia’s pipelines to Europe, before 2022, ran 3,000 to 4,000 km from Western Siberia.
Where oceans or long distances make pipelines impractical, gas is liquefied and shipped instead; see the LNG value chain.
Storage: banking summer gas for winter
Gas demand in cold countries can be three to five times higher on a winter day than in summer, but fields and pipelines are most efficient running steadily. Storage fills the gap.
| Storage type | How it works | Typical role |
|---|---|---|
| Depleted gas fields | Gas pumped back into former reservoirs | Large seasonal storage, slow to cycle |
| Aquifers | Gas displaces water in porous rock | Seasonal, common in France and the US Midwest |
| Salt caverns | Cavities dissolved in salt domes | Fast injection and withdrawal for daily and weekly swings |
| LNG peak-shaving tanks | Gas liquefied and stored above ground | Coldest days in cities without underground storage |
The EU holds roughly 100 billion m³ of storage capacity. After the 2022 crisis it required member states to fill storage to 90% before winter, with some flexibility on timing added in 2025. Daily fill levels are public on the GIE AGSI+ platform. Storage levels are one of the main drivers of seasonal price swings, covered in how gas prices are set.
Distribution: from city gate to your meter
At the city gate, a regulating station cuts pressure and meters the gas handed from the transmission operator to the local distribution company. Here, or nearby, the odorant is added. Methane is odourless, so utilities inject small amounts of a sulphur compound, commonly a mercaptan blend or tetrahydrothiophene (THT). The aim is that a leak becomes noticeable at around 1% gas in air, one-fifth of the 5% lower flammability limit.
Pressure steps down again through district regulators. Medium-pressure mains run under main roads; low-pressure polyethylene pipes branch into streets. A service pipe enters each building through a final regulator and the meter. By the time it reaches a European hob, gas is at about 20 millibar, around 2% above atmospheric pressure.
Many older cities still have cast-iron mains that leak at the joints. Replacement programmes in the UK, the US and elsewhere aim to cut both methane emissions and explosion risk. The methane leakage entry explains why small leaks matter for climate.
Metering and the units on your bill
Most household meters measure volume, not energy. A diaphragm meter counts cubic metres or cubic feet as gas fills and empties small chambers. Your bill then converts volume into energy using the gas’s calorific value, which typically ranges from about 37 to 42 MJ/m³.
| Where | Meter reads in | Billed in |
|---|---|---|
| UK, EU | m³ (or ft³ on old UK meters) | kWh |
| United States | ccf (100 ft³) | Therms (1 therm = 100,000 Btu ≈ 29.3 kWh) |
| Malaysia (Gas Malaysia) | m³ | RM per MMBtu, converted from m³ |
UK example: 100 m³ × 1.02264 (volume correction) × 39.5 MJ/m³ ÷ 3.6 ≈ 1,122 kWh
Convert your own readings with the gas unit converter and estimate the cost with the gas cost calculator.
At the burner
Gas burns with a blue flame when it mixes with enough air. Efficiency depends on the appliance:
- Condensing boilers: about 89 to 94% seasonal efficiency when return water is cool enough to condense the flue vapour.
- Gas hobs: only about 30 to 40% of the heat reaches the pan. Induction hobs manage roughly 80 to 90%.
- Gas water heaters: 60 to 95% depending on whether they are condensing and how much heat the tank loses.
Burning gas indoors also releases nitrogen dioxide and fine particles, so kitchens need ventilation. For heating, compare boilers with heat pumps in the heat pump vs gas boiler calculator.
What to remember
Gas reaches you through five stages: production, processing, high-pressure transmission, storage and low-pressure distribution, with an odorant added so you can smell leaks. Bills convert measured volume into energy, so it helps to know your calorific value and units. For country-level gas use, see the natural gas dashboard, the natural gas technology page and the world energy map.
Calculators for this topic
Frequently asked questions
Why does natural gas smell if methane has no odour?
What pressure is gas at in the pipes?
How is gas stored for winter?
What is the difference between a therm, a ccf and a kWh of gas?
Is cooking with gas worse than induction?
How much natural gas leaks between the well and the customer?
Sources & references
Figures in this guide are typical ranges drawn from the sources above; your own numbers depend on location, prices and equipment. Use the linked calculators for site-specific estimates.