Energy finance calculator

LCOS calculator: levelized cost of storage for batteries and other storage

Levelized cost per MWh discharged for a battery or other storage system from capex per kWh, O&M, cycles, depth of discharge, round-trip efficiency, degradation, life, discount rate and charging price, with the price spread it needs.

Editable share link Branded PDF report Free · no sign-up

Results

Each MWh discharged costs 170 $ over the project life: 104.4 for capital, 19 for O&M and 46.5 for charging energy (including losses). The system must earn about 130 $/MWh more than it pays for charging power. At an average selling price of 140 $/MWh it does not cover its costs.
LCOS
170$/MWh
0.17 $ per kWh
Capital share
104.4$/MWh
O&M share
19$/MWh
Charging share
46.5$/MWh
86% round trip
Required spread
130$/MWh
selling minus charging price
Energy capacity
400MWh
Installed cost
100million $
Discharged in year 1
118,800MWh
Capacity at end of life
72%
LCOS breakdown ($/MWh)
LCOS vs cycles per year

Yearly operation

YearCapacityMWh dischargedO&M ($)Charging cost ($)
1100%118,8002,000,0005,525,581
298%116,4242,000,0005,415,070
396%114,0482,000,0005,304,558
494%111,6722,000,0005,194,047
592%109,2962,000,0005,083,535
690%106,9202,000,0004,973,023
788%104,5442,000,0004,862,512
886%102,1682,000,0004,752,000
984%99,7922,000,0004,641,488
1082%97,4162,000,0004,530,977
1180%95,0402,000,0004,420,465
1278%92,6642,000,0004,309,953
1376%90,2882,000,0004,199,442
1474%87,9122,000,0004,088,930
1572%85,5362,000,0003,978,419
  • Linear capacity fade, no augmentation or cell replacement; real projects often add modules to hold capacity. Calendar ageing at low cycling is not modelled separately.
  • LCOS is pre-tax and in real terms; it excludes grid connection fees, capacity payments and ancillary service revenues. Battery prices have fallen fast; enter a current quote.

What LCOS tells you

Batteries, pumped hydro and other storage do not generate energy; they buy it, keep it for a while and sell it back, losing some on the way. Their cost per MWh delivered depends on how much they cost to build, how often they cycle, how efficient they are, how fast they age and how much the charging electricity costs. The levelized cost of storage (LCOS) rolls all of that into one figure per MWh discharged, so storage options can be compared with each other and with the price spreads they will earn.

This calculator follows the standard definition used by Lazard and by Schmidt et al. in Joule (2019). Costs and energy are discounted at your WACC, capacity fades every year, and charging energy includes round-trip losses.

The formula

LCOS = [capex + Σ O&M_t ÷ (1+r)^t + Σ (E_out,t ÷ η_RT × P_charge) ÷ (1+r)^t] ÷ Σ E_out,t ÷ (1+r)^t

E_out,t = MW × hours × DoD × SOH_t × cycles per year SOH_t = 1 − capacity loss × (t − 1) (not below 50%)

Required spread = LCOS − charging price

O&M is entered as a share of capex per year, the common convention for batteries. Augmentation, cell replacement and end-of-life value are left out, so the result is conservative for projects that add modules to hold capacity.

Worked example

The defaults describe a 100 MW / 4-hour battery (400 MWh) at 250 per kWh installed, with 2% O&M per year, 330 full cycles a year at 90% depth of discharge, 86% round-trip efficiency, 2% capacity loss a year, a 15-year life, a 7% WACC and charging power at 40 per MWh.

  • Capex: 400 MWh × 250,000 = 100 million.
  • Year-one discharge: 400 × 0.9 × 330 = 118,800 MWh. By year 15 capacity has fallen to 72%.
  • Present value of discharged energy: about 957,000 MWh. Capital alone is 100 million ÷ 957,000 ≈ 104 per MWh.
  • O&M adds about 19 per MWh. Charging adds 40 ÷ 0.86 ≈ 46.5 per MWh.
  • LCOS ≈ 170 per MWh. The battery must sell its output for about 130 per MWh more than it pays for charging power, on average. At an average selling price of 140 it would not cover its costs from arbitrage alone, which is why most batteries stack revenues from capacity markets and grid services.

The cycles chart shows the main lever: at 200 cycles a year the LCOS rises well above 200, while at 500 it falls below 140, if the cells can handle it.

Typical values

Storage type Round-trip efficiency Typical installed cost Typical LCOS (per MWh)
Utility LFP battery, 4 h 85–90% 200–350 per kWh 100–250
Utility LFP battery, 1–2 h 86–90% 300–500 per kWh 120–300
Home battery (5–15 kWh) 88–92% 500–1,000 per kWh 250–500
Pumped hydro, 8 h+ 75–80% 100–250 per kWh 70–150
Hydrogen (power-to-power) 30–40% varies widely > 300

Ranges are indicative and vary by market, year and financing. Battery pack prices fell steeply between 2022 and 2024, so use a current quote.

How to read the results

  • LCOS is the average break-even price per MWh discharged.
  • Required spread is the margin above the charging price the system must earn on average. Compare it with the peak/off-peak spread in your market; the time-of-use savings calculator shows the spread on retail tariffs.
  • The breakdown shows whether capital, O&M or charging energy dominates. Charging cost matters more for low-efficiency technologies.
  • The yearly table shows how degradation reduces output.

Limitations

LCOS ignores revenue stacking: capacity payments, frequency response, avoided demand charges and deferred network investment. These often make a storage project viable when arbitrage alone does not. Degradation depends on temperature, C-rate and cycling depth, not only on years. Taxes, grid fees and financing structures are left out. To value demand-charge savings, use the demand charge calculator; for generators, the LCOE calculator.

Method & assumptions

LCOS = [capex + Σ O&Mt/(1+r)t + Σ (Eout,t ÷ ηRT × Pcharge)/(1+r)t] ÷ Σ Eout,t/(1+r)t. Eout,t = rated MWh × depth of discharge × state of healtht × cycles; state of health falls linearly by the capacity loss per year (floor 50%). O&M is a % of capex per year.

Frequently asked questions

What is the levelized cost of storage (LCOS)?
LCOS is the average cost of each MWh a storage system delivers over its life, including capital, operation and maintenance and the electricity bought to charge it, all discounted to present value. It is the storage equivalent of LCOE and tells you the average price a battery must earn per MWh discharged to break even.
How is LCOS calculated?
LCOS = (capex + present value of O&M + present value of charging costs) ÷ present value of MWh discharged. Discharged energy each year = rated MWh × depth of discharge × remaining capacity × cycles per year. Charging energy = discharged energy ÷ round-trip efficiency.
What is a typical LCOS for a lithium-ion battery?
For utility-scale 4-hour lithium iron phosphate (LFP) systems, published estimates in 2023–2025 mostly fall around 100–250 USD per MWh discharged, depending on capex, cycles, financing and the charging price. Lazard's annual LCOS analysis is a widely used benchmark. Home batteries cycle less and cost more per kWh, so their LCOS is often 250–500 per MWh.
Why do cycles per year matter so much?
Capital is a fixed cost spread over the MWh discharged. A battery cycling once a day spreads it over twice the energy of one cycling every other day, roughly halving the capital part of LCOS, until cycle-life limits or degradation take over.
What round-trip efficiency should I use?
AC-to-AC round-trip efficiency, including the inverter, transformer and auxiliary loads, is typically 85–90% for new LFP battery systems, 75–80% for pumped hydro, 60–70% for compressed air and 30–40% for hydrogen (electrolysis, storage and re-electrification).
What is the difference between LCOS and LCOE?
LCOE covers a generator and its fuel. LCOS covers a device that buys electricity and sells it later, so it includes the cost of charging energy and the losses. A storage project makes money from price spreads, capacity payments and grid services, not from producing energy.

Sources & references

  1. Lazard — Levelized Cost of Energy+ (includes LCOS analysis)
  2. Schmidt et al. (2019), Projecting the future levelized cost of electricity storage technologies, Joule 3(1)
  3. NREL — Annual Technology Baseline: utility-scale battery storage
  4. IRENA — Electricity Storage and Renewables: Costs and Markets to 2030

Embed this calculator

Free for blogs, installers, schools and NGOs. Copy the code below; it updates itself automatically.