How this firewood calculator works
Firewood is sold by volume (cords, face cords, steres, bulk bags) or by weight, but what you are really buying is dry wood fibre, and water you will have to boil off. This calculator works out how much dry wood is in each unit, how much energy it releases at your moisture content, and how much of that your stove turns into room heat. From there it gives the cost per kWh of heat, the amount you need for a winter and what the same heat would cost in heating oil.
For stacked units it multiplies the stacked volume by the share of solid wood (65% for well-stacked split logs, 45% for loosely thrown logs) and by the species’ basic density, the oven-dry mass per cubic metre of fresh wood from the USDA Wood Handbook and European tables. For units sold by weight, it takes the dry share of that weight. The energy then comes from the net calorific value of dry wood (18.5–19.2 MJ/kg), reduced by the water in the wood and the heat needed to evaporate it.
The formula
Useful heat = energy × stove efficiency × wet-wood penalty Wet-wood penalty = 1 − 1% per point of moisture above 20% Cost per kWh of heat = price ÷ useful heat
Here w is the moisture content on a wet basis (water as a share of total weight) and 2.443 MJ/kg is the energy needed to evaporate water.
Worked example
The defaults are a stere of beech at 20% moisture, costing €95, burned in a modern stove at 75% efficiency, with 8,000 kWh of heat wanted from wood each year.
- Dry wood: 1 m³ × 0.65 × 560 kg/m³ = 364 kg; with the water, the stere weighs about 455 kg (91 kg of it water).
- Energy content: 18.7 × 0.8 − 2.443 × 0.2 = 14.5 MJ/kg, so 455 kg holds about 1,830 kWh (6.6 GJ).
- Useful heat: 1,830 × 0.75 ≈ 1,370 kWh, so heat costs €95 ÷ 1,370 ≈ €0.069/kWh.
- For 8,000 kWh you need about 5.8 steres, costing €554 a year.
- An 85% oil boiler would need about 161 litres of oil for the same heat, worth €178 at €1.10/L.
Now try the same stere at 45% moisture. It gives only about 950 kWh of heat, 31% less, and heat costs €0.10/kWh. The water has to be boiled off, and the cooler, smokier fire burns less completely.
How to read the results
- Energy per unit is what is in the wood; useful heat is what reaches the room.
- Cost per kWh of heat is the number to compare with other fuels. Use heating cost comparison for a full side-by-side.
- Weight per unit and water in each unit show how much of what you carry in is water.
- The moisture chart shows how fast the cost climbs once wood is wetter than 20 to 25%.
Typical values
| Species | Basic density (kg/m³) | kWh per stere at 20% | kWh per cord at 20% |
|---|---|---|---|
| Hornbeam | 640 | about 2,080 | about 7,500 |
| Oak | 600 | about 1,960 | about 7,100 |
| Beech / hard maple | 560 | about 1,830 | about 6,600 |
| Birch | 500 | about 1,660 | about 6,000 |
| Pine | 420 | about 1,410 | about 5,100 |
| Spruce / fir | 370 | about 1,240 | about 4,500 |
| Appliance | Typical efficiency |
|---|---|
| Open fireplace | 10–20% |
| Older stove | 50–65% |
| Modern certified stove | 75–85% |
| Log gasification boiler | 85–90% |
Tips for getting more heat from wood
- Buy a season ahead. Split, stacked and covered with open sides, hardwood usually needs one to two years to drop below 20%.
- Measure moisture. A cheap meter on a freshly split face tells you more than any seller’s promise.
- Check the stack. Ask what a “cord” or “load” means locally and how tightly it is stacked; loosely thrown wood holds about a third less than a neat stack.
- Upgrade the appliance. Moving from an open fire to a modern stove can triple the heat from the same wood.
- Compare by kWh, not by volume. A cheaper stere of poplar can cost more per kWh than a dearer stere of oak.
Limitations
Basic densities are species averages and individual trees vary by about ±10%. Solid fractions assume reasonably straight split logs; crooked or large rounds stack differently. The wet-wood penalty on efficiency is a simple rule of thumb. The calculator does not cover pellets, chips or boiler sizing; for those, use the biomass boiler calculator. For other fuels’ energy content, see fuel energy content.
Method & assumptions
Dry wood per unit = stacked volume × solid fraction × basic density (or weight × (1 − moisture) for tonnes and bags). Net calorific value as received = NCVdry × (1 − w) − 2.443 × w MJ/kg, where w is the moisture fraction and 2.443 MJ/kg is the heat to evaporate water. Energy per unit = wet mass × NCV ÷ 3.6. Useful heat = energy × stove efficiency, reduced by 1% (relative) for each point of moisture above 20% because wet wood burns cooler and less completely. Cost per kWh = price ÷ useful heat.
Frequently asked questions
How many kWh are in a cord of firewood?
How much heat is in a stere of wood?
What is the best firewood to burn?
How dry should firewood be?
How much firewood do I need for a winter?
Is firewood cheaper than heating oil or gas?
Sources & references
Embed this calculator
Free for blogs, installers, schools and NGOs. Copy the code below; it updates itself automatically.