Heating & gas calculator

How much does a space heater cost to run?

Works out what an electric space heater (oil-filled, fan, convector, infrared, ceramic), a split heat pump, an LPG cabinet heater or a kerosene heater costs per hour, per day and per winter, and checks whether its power is enough for the room you want to heat.

Editable share link Branded PDF report Free · no sign-up

Results

This heater costs about 0.42 € per hour at full power and 1.51 € per day as you use it, or 181 € over 120 days. Its 1.5 kW of heat is enough for a 16 m² room (needs about 1.1 kW).
Cost per winter
€181
648 kWh of electricity
Cost per hour at full power
€0.42
Cost per day
€1.51
6 h on, 60% duty cycle
Cost per month
€45.96
Cost per kWh of heat
€0.28
all input becomes heat
Heat output
1.5kW
room needs ≈ 1.1 kW
Fuel used per winter
648kWh
Same heat from each heater type: cost per winter

Cost per kWh of heat delivered

Heater€/kWh of heat
Oil-filled radiator0.28
Fan heater0.28
Convector / panel heater0.28
Infrared / halogen heater0.28
Ceramic heater0.28
Air-to-air heat pump (split AC)0.088
LPG cabinet heater0.203
Kerosene / paraffin heater0.208
  • All electric resistance heaters (oil-filled, fan, convector, ceramic, infrared) are 100% efficient at turning electricity into heat. An “energy-saving” claim for one of them can only come from better controls or from heating people rather than air (infrared). Only a heat pump delivers more heat than the electricity it uses.
  • Unflued LPG and kerosene heaters release water vapour, CO₂ and nitrogen dioxide into the room; they need ventilation and are banned in bedrooms in many countries.
  • Room heat need: about 100 W/m² for a poorly insulated room, 70 for average and 45 for a well-insulated one at around −5 °C outside.

How this space heater calculator works

Space heaters are simple machines, which makes their running cost easy to work out once you know three things: how much power the heater draws, how much of the time it actually runs, and what you pay per kWh. This calculator takes the heater’s input power and your price to get the cost per hour on full, applies a duty cycle for the time the thermostat keeps it switched on, and multiplies up to a day, a month and a whole winter.

It also does two checks people often skip. The first compares the heater’s output with the heat a room of your size and insulation needs in cold weather, so you can see if it will cope or run flat out all day. The second puts every heater type side by side for the same amount of heat, which shows why the type of electric heater matters much less than the advertising suggests, and why a heat pump is in a different league.

The formula

Cost per hour on full = input power (kW) × price per kWh (LPG: price per kg ÷ 12.8 kWh/kg; kerosene: price per litre ÷ 9.6 kWh/L) Real cost per hour = full-power cost × duty cycle Cost per day = real cost per hour × hours on Cost per winter = cost per day × days of use

Heat output = input × COP (COP = 1 for resistance and flame heaters) Room heat need = floor area × 45 / 70 / 100 W/m²

Worked example

The defaults describe a 1.5 kW oil-filled radiator switched on 6 hours a day for 120 days of winter, with the thermostat keeping it running 60% of the time. Electricity costs €0.28/kWh. The room is 16 m² with average insulation.

  • On full power: 1.5 × €0.28 = €0.42 an hour.
  • With the thermostat cycling: €0.42 × 0.6 = €0.25 an hour, so €1.51 a day.
  • Over the winter: €1.51 × 120 = €181, for 648 kWh of electricity (about €46 a month).
  • Every kWh of heat costs €0.28, because all the electricity becomes heat.
  • The room needs about 16 × 70 W = 1.1 kW in cold weather, so the 1.5 kW heater has some margin.

In the comparison chart, every resistance heater lands on the same €181. A split air conditioner heating with a COP of 3.2 would deliver the same heat for about €57. An LPG cabinet heater would cost around €132 and a kerosene heater €135 at the default fuel prices.

How to read the results

  • Cost per winter is the headline, based on your hours and duty cycle.
  • Cost per hour at full power is the worst case, for example while warming a cold room.
  • Heat output vs room need: if the output is below the need, the heater will run continuously in cold weather and the room may still not reach temperature. Raise the duty cycle to 100% to see that cost.
  • Cost per kWh of heat compares directly with other heating. The heating cost comparison does the same for boilers and heat pumps.

Typical values

Heater Typical power Heat per kWh of input
Oil-filled radiator 1–2.5 kW 1 kWh
Fan heater 2–3 kW 1 kWh
Convector / panel heater 1–2.5 kW 1 kWh
Infrared / halogen 0.4–2 kW 1 kWh (heats people, not air)
Split heat pump (heating) 0.5–1.5 kW input 2.5–4 kWh
LPG cabinet heater 1.5–4.2 kW 1 kWh of gas
Kerosene heater 2–3 kW 1 kWh of fuel

Tips to cut space heater costs

  • Heat the room you are in, not the house. Used this way, a small heater can save money compared with heating every room.
  • Use the thermostat and a timer. A heater left on full in an empty room is the most common waste.
  • Close the door and block draughts. The heater only needs to cover the room’s losses.
  • Consider infrared for spot heating. In a draughty workshop or at a desk, warming you directly with a few hundred watts beats heating all the air.
  • Look at a heat pump. If you heat one room most of the winter, a split unit costs about a third as much to run. The heat pump calculator shows the numbers for a whole house, and the air conditioner cost calculator covers sizing.

Limitations

The duty cycle is a single average; real cycling depends on outdoor temperature, insulation and the thermostat setting. The room heat need uses simple W/m² rules for about −5 °C outside and a 2.5 m ceiling, so treat it as a sanity check, not a heat-loss calculation. Heat pump COP falls in very cold weather. Fuel prices for LPG and kerosene vary widely, and bottled kerosene in particular costs much more than bulk heating oil.

Method & assumptions

Cost per hour at full power = input kW × price per kWh (LPG price ÷ 12.8 kWh/kg, kerosene price ÷ 9.6 kWh/L). Real cost per hour = full-power cost × duty cycle. Day = hourly cost × hours; winter = day × days. Heat output = input × COP (1 for resistance and flame heaters). Room need = area × W/m² for the insulation level.

Frequently asked questions

How much does it cost to run a space heater per hour?
Multiply the heater's power in kW by your electricity price. A 1.5 kW heater at €0.28/kWh costs €0.42 an hour on full power; a 2 kW fan heater €0.56. Once the room is warm the thermostat cycles the heater, so the real hourly cost is often 50–70% of that.
Which type of electric heater is cheapest to run?
For the same heat, all resistance heaters cost exactly the same: oil-filled radiators, fan, convector, ceramic and infrared heaters all turn 100% of their electricity into heat. Differences come from controls and how the heat reaches you. Only a heat pump (such as a split air conditioner in heating mode) delivers more heat than the electricity it uses, typically 2.5–4 times more.
Is an oil-filled radiator cheaper than a fan heater?
Not per kWh of heat. An oil-filled radiator gives gentler, longer-lasting warmth and usually has a lower power rating, so it uses less per hour, but it also delivers less heat per hour. For heating a room to the same temperature for the same time, the energy is similar.
What size heater do I need for my room?
As a rough guide, about 45 W per m² for a well-insulated room, 70 W/m² for an average one and 100 W/m² for an old, poorly insulated room in cold weather. A 16 m² average room needs about 1.1 kW.
Is it cheaper to use a space heater than central heating?
It can be, if you heat one room for a few hours instead of the whole house. Per kWh of heat, though, electric resistance heating is usually two to three times dearer than a gas boiler and about three times dearer than a heat pump.
Are LPG and kerosene heaters safe indoors?
They release water vapour, carbon dioxide and nitrogen dioxide into the room and need ventilation. Many countries ban unflued heaters in bedrooms and bathrooms. Use them only with a working carbon monoxide alarm and a slightly open window.

Sources & references

  1. US DOE Energy Saver: Portable Heaters
  2. US DOE Energy Saver: Electric Resistance Heating
  3. US EPA: Nitrogen Dioxide's Impact on Indoor Air Quality

Embed this calculator