Carbon & climate calculator

Scope 2 emissions calculator: location-based and market-based CO₂

Calculate Scope 2 emissions from purchased electricity, heat and steam with both GHG Protocol methods: location-based (grid average) and market-based (renewable certificates, PPAs, green tariffs, supplier factors and the residual mix).

Editable share link Branded PDF report Free · no sign-up

Results

Location-based Scope 2 is 1,650 t CO₂e (Germany, 330 kg/MWh). Market-based Scope 2 is 1,500 t CO₂e: 50% of the electricity is covered by renewable PPAs or certificates and 2,500 MWh is counted at the residual mix of 600 kg/MWh.
Market-based Scope 2
1,500t CO₂e
Location-based Scope 2
1,650t CO₂e
grid factor 330 kg/MWh
Difference
150t CO₂e
Renewable share (market-based)
50%
Covered by PPA
1,000MWh
Covered by certificates
1,500MWh
At residual mix
2,500MWh
1,500 t CO₂e
Market-based intensity
300kg CO₂e/MWh
On-site solar (outside Scope 2)
300MWh
avoids 99 t vs the grid average
Scope 2 by method (t CO₂e)
How the electricity is covered (MWh)

Market-based calculation

SourceMWhFactor (kg CO₂e/MWh)t CO₂e
Renewable PPA1,00000
Certificates1,50000
Supplier tariff02500
Residual mix2,5006001,500
Purchased heat / steam02500
  • Grid factors in the list are lifecycle averages (g CO₂e/kWh, OWID/Ember). For official reporting use the factor your programme requires (e.g. IEA, national inventory, US eGRID) and residual mixes such as AIB (Europe) or Green-e (US).
  • Market instruments must meet the GHG Protocol Scope 2 quality criteria (same market, vintage, retired on your behalf). The GHG Protocol is revising its Scope 2 guidance; check the current version.

What this calculator does

Almost every company that reports greenhouse gas emissions has to report Scope 2: the emissions caused by the electricity, heat, steam and cooling it buys. Since the 2015 GHG Protocol Scope 2 Guidance, that means two numbers. The location-based figure uses the average emission factor of the local grid. The market-based figure reflects the company’s purchasing choices: renewable PPAs, energy attribute certificates (RECs in North America, Guarantees of Origin in Europe, I-RECs elsewhere), green tariffs and supplier-specific factors.

This calculator produces both figures from your annual consumption and contracts. It applies instruments only up to total consumption and counts the uncovered remainder at the residual mix. The table shows each line so you can carry it into a report.

The formula

Location-based = Σ MWh_grid × average grid factor (+ purchased heat × heat factor)

Market-based = MWh_PPA × 0 + MWh_certificates × 0 + MWh_supplier × supplier factor + MWh_uncovered × residual mix factor (+ purchased heat × heat factor)

MWh_uncovered = consumption − (PPA + certificates + supplier-specific), not below zero

Instruments are applied in the order PPA, then certificates, then supplier tariff. In practice the order only matters when they add up to more than you consumed, in which case the surplus cannot be claimed.

Worked example

The defaults describe an organisation in Germany buying 5,000 MWh a year. It holds a 1,000 MWh renewable PPA and 1,500 MWh of Guarantees of Origin, and its residual-mix factor is 600 kg CO₂e/MWh. It also uses 300 MWh from rooftop solar it owns.

  • Location-based: 5,000 × 330 kg/MWh (Germany’s latest average in the dataset) = 1,650 t CO₂e.
  • Market-based: the PPA and certificates cover 2,500 MWh at zero. The other 2,500 MWh at 600 kg/MWh = 1,500 t CO₂e.
  • Renewable share for market-based reporting: 50%. Market-based intensity: 300 kg/MWh.
  • The on-site solar is outside Scope 2. It avoided buying 300 MWh, worth about 99 t at the grid average.

The market-based figure is only 150 t lower even though half the electricity is covered. The residual mix is much dirtier than the average, because others have already claimed the clean power. Cover all 5,000 MWh with certificates (second preset) and market-based Scope 2 falls to zero, while location-based stays at 1,650 t.

Which factors to use

Item Typical source
Location-based grid factor IEA emission factors, national inventory, US eGRID subregion, or the grid averages in this tool
Residual mix (Europe) AIB European Residual Mixes, published annually
Residual mix (US) Green-e Residual Mix
Supplier-specific factor The supplier’s fuel-mix disclosure for your tariff
Purchased heat / steam The district heating or steam supplier

The grid list in this calculator uses lifecycle averages from Our World in Data / Ember, which are fine for estimates. Formal disclosures often require combustion-only factors from a named source; switch to the custom factor to enter one.

How to read the results

  • Market-based Scope 2 is the figure most companies use for targets and RE100 claims, if the instruments meet the quality criteria.
  • Location-based Scope 2 shows the physical grid impact of your consumption. Cutting it requires using less electricity or moving it to cleaner hours or places.
  • The difference is what your contracts are worth in reported emissions.
  • Market-based intensity is useful for comparing sites or suppliers.

Limitations

This is a single-site annual calculation. Companies with sites in several countries must calculate each location with its own factors and instruments. Hourly matching (“24/7 carbon-free energy”) and the revised Scope 2 rules under discussion at the GHG Protocol are not modelled. Transmission and distribution losses belong to Scope 3 (category 3) for most companies. For a quick kWh-to-CO₂ conversion by country, use the electricity CO₂ calculator; to build a grid factor from a generation mix, the grid emission factor calculator.

Method & assumptions

Location-based = grid MWh × average grid emission factor (+ purchased heat × its factor). Market-based = Σ MWh covered by each contractual instrument × its factor (renewable PPAs and certificates = 0; supplier-specific factor) + uncovered MWh × residual mix factor (+ heat). Instruments are applied up to total consumption only. Self-generated electricity is not purchased and is therefore outside Scope 2.

Frequently asked questions

What are Scope 2 emissions?
Scope 2 covers the indirect greenhouse gas emissions from electricity, steam, heat and cooling that a company buys and uses. The emissions physically happen at the power station or heating plant, but they are attributed to the buyer under the GHG Protocol Corporate Standard.
What is the difference between location-based and market-based Scope 2?
Location-based uses the average emission factor of the grid where the electricity is consumed, regardless of contracts. Market-based reflects the electricity the company has chosen to buy: renewable certificates, PPAs, green tariffs and supplier-specific factors, with uncovered consumption counted at the residual mix. The GHG Protocol requires companies to report both (dual reporting).
How do I calculate location-based Scope 2 emissions?
Multiply the electricity consumed in each location by that grid's average emission factor and add them up. 5,000 MWh in a grid averaging 330 kg CO₂e/MWh gives 1,650 t CO₂e. Add purchased heat or steam multiplied by its supplier's factor.
What is a residual mix factor?
The residual mix is the emission factor of the electricity left over once all renewable certificates and other claims have been removed from the grid mix. Because the clean MWh were claimed by others, the residual mix is usually higher than the grid average. In Europe the AIB publishes residual mixes each year; in the US Green-e does.
Do renewable energy certificates reduce Scope 2 emissions?
They reduce market-based Scope 2 if they meet the GHG Protocol quality criteria: from the same market as the consumption, from a similar time period, and retired on your behalf. They do not change location-based Scope 2. Whether unbundled certificates drive new renewable capacity is debated, which is one reason the GHG Protocol is revising its Scope 2 guidance.
Is electricity from my own solar panels Scope 2?
No. Electricity you generate and use yourself is not purchased, so it has no Scope 2 emissions (and solar has no Scope 1 combustion emissions). It reduces the amount you buy from the grid. Electricity bought from a third-party-owned system on your roof under a PPA is Scope 2, with a zero market-based factor if the certificates come with it.

Sources & references

  1. GHG Protocol — Scope 2 Guidance (2015, amendment to the Corporate Standard)
  2. Association of Issuing Bodies (AIB) — European Residual Mixes
  3. US EPA — eGRID (Emissions & Generation Resource Integrated Database)
  4. Our World in Data / Ember — Carbon intensity of electricity generation

Embed this calculator