What this calculator does
Almost every company that reports greenhouse gas emissions has to report Scope 2: the emissions caused by the electricity, heat, steam and cooling it buys. Since the 2015 GHG Protocol Scope 2 Guidance, that means two numbers. The location-based figure uses the average emission factor of the local grid. The market-based figure reflects the company’s purchasing choices: renewable PPAs, energy attribute certificates (RECs in North America, Guarantees of Origin in Europe, I-RECs elsewhere), green tariffs and supplier-specific factors.
This calculator produces both figures from your annual consumption and contracts. It applies instruments only up to total consumption and counts the uncovered remainder at the residual mix. The table shows each line so you can carry it into a report.
The formula
Market-based = MWh_PPA × 0 + MWh_certificates × 0 + MWh_supplier × supplier factor + MWh_uncovered × residual mix factor (+ purchased heat × heat factor)
MWh_uncovered = consumption − (PPA + certificates + supplier-specific), not below zero
Instruments are applied in the order PPA, then certificates, then supplier tariff. In practice the order only matters when they add up to more than you consumed, in which case the surplus cannot be claimed.
Worked example
The defaults describe an organisation in Germany buying 5,000 MWh a year. It holds a 1,000 MWh renewable PPA and 1,500 MWh of Guarantees of Origin, and its residual-mix factor is 600 kg CO₂e/MWh. It also uses 300 MWh from rooftop solar it owns.
- Location-based: 5,000 × 330 kg/MWh (Germany’s latest average in the dataset) = 1,650 t CO₂e.
- Market-based: the PPA and certificates cover 2,500 MWh at zero. The other 2,500 MWh at 600 kg/MWh = 1,500 t CO₂e.
- Renewable share for market-based reporting: 50%. Market-based intensity: 300 kg/MWh.
- The on-site solar is outside Scope 2. It avoided buying 300 MWh, worth about 99 t at the grid average.
The market-based figure is only 150 t lower even though half the electricity is covered. The residual mix is much dirtier than the average, because others have already claimed the clean power. Cover all 5,000 MWh with certificates (second preset) and market-based Scope 2 falls to zero, while location-based stays at 1,650 t.
Which factors to use
| Item | Typical source |
|---|---|
| Location-based grid factor | IEA emission factors, national inventory, US eGRID subregion, or the grid averages in this tool |
| Residual mix (Europe) | AIB European Residual Mixes, published annually |
| Residual mix (US) | Green-e Residual Mix |
| Supplier-specific factor | The supplier’s fuel-mix disclosure for your tariff |
| Purchased heat / steam | The district heating or steam supplier |
The grid list in this calculator uses lifecycle averages from Our World in Data / Ember, which are fine for estimates. Formal disclosures often require combustion-only factors from a named source; switch to the custom factor to enter one.
How to read the results
- Market-based Scope 2 is the figure most companies use for targets and RE100 claims, if the instruments meet the quality criteria.
- Location-based Scope 2 shows the physical grid impact of your consumption. Cutting it requires using less electricity or moving it to cleaner hours or places.
- The difference is what your contracts are worth in reported emissions.
- Market-based intensity is useful for comparing sites or suppliers.
Limitations
This is a single-site annual calculation. Companies with sites in several countries must calculate each location with its own factors and instruments. Hourly matching (“24/7 carbon-free energy”) and the revised Scope 2 rules under discussion at the GHG Protocol are not modelled. Transmission and distribution losses belong to Scope 3 (category 3) for most companies. For a quick kWh-to-CO₂ conversion by country, use the electricity CO₂ calculator; to build a grid factor from a generation mix, the grid emission factor calculator.
Method & assumptions
Location-based = grid MWh × average grid emission factor (+ purchased heat × its factor). Market-based = Σ MWh covered by each contractual instrument × its factor (renewable PPAs and certificates = 0; supplier-specific factor) + uncovered MWh × residual mix factor (+ heat). Instruments are applied up to total consumption only. Self-generated electricity is not purchased and is therefore outside Scope 2.
Frequently asked questions
What are Scope 2 emissions?
What is the difference between location-based and market-based Scope 2?
How do I calculate location-based Scope 2 emissions?
What is a residual mix factor?
Do renewable energy certificates reduce Scope 2 emissions?
Is electricity from my own solar panels Scope 2?
Sources & references
Embed this calculator
Free for blogs, installers, schools and NGOs. Copy the code below; it updates itself automatically.