How this calculator works
Rooftop solar in Malaysia is no longer a simple “export everything and net it off” deal. Since 1 January 2026, new home systems in Peninsular Malaysia join Solar ATAP, where the value of each solar kWh depends on whether you use it yourself or send it to the grid. This calculator models both, hour by hour.
It downloads a full year of hourly satellite weather from NASA POWER for your location, simulates your panels’ output for all 8,760 hours (sun position, irradiance on a tilted roof, cell temperature and inverter clipping at the Solar ATAP limit), and lays a typical Malaysian household load shape over it. Solar used in the same hour as your demand is self-consumption. The rest is export. Each month it then computes two TNB bills: your bill without solar, and your bill for the remaining grid imports minus the Solar ATAP export credit.
The Solar ATAP rules we apply
From the Energy Commission guideline (GP/ST/No. 60/2025, effective 1 January 2026):
- Domestic systems: up to 5 kWac on single-phase supply, up to 15 kWac on three-phase.
- Exports from homes are credited at the energy charge rate only, not the capacity or network charges.
- Credits offset imports in the same billing period; unused credit is forfeited and cannot offset the AFA.
- Exports count only up to the maximum allowable quantity: kWac × 5 hours × days in the period.
- The Solar ATAP contract lasts up to 10 years; afterwards the system continues for self-consumption.
The formula
A solar kWh you use yourself avoids the energy, capacity and network charges (44.43 sen/kWh before rebates) and can also keep you under the thresholds where AFA, the retail charge and SST apply. An exported kWh earns 27.03 sen. That gap is why systems sized to cover daytime use pay back fastest.
Worked example: a 6 kWp system in Kuala Lumpur
The default is a terrace house in KL using 900 kWh a month, with a 6 kWp system on a 15° south-facing roof, three-phase supply and an installed price of RM21,000 (RM3,500 per kWp).
- Production: about 6,740 kWh a year (about 1,120 kWh per kWp) with 2024 NASA weather.
- About 53% of the solar is used directly; the rest is exported and fully credited because exports stay below both imports and the monthly cap.
- The TNB bill falls from about RM452 to around RM150 a month on average, a first-year saving of about RM3,600.
- Payback in about 6 years, with an internal rate of return around 17% over 25 years.
These numbers move with the weather year you choose, the AFA rate and your actual daytime use.
How to read the results
- Bill saving, year 1 is the difference between the two bills summed over 12 months.
- Used directly at home is the self-consumption share. Raising it (timers for washing, dishwashers and water heaters, pre-cooling the house in the afternoon, charging an EV at home in the daytime) raises the saving.
- Exports without credit appear when the system is too large for your usage or exceeds the monthly cap. If this number is large, a smaller system or a battery may make more sense.
- The month-by-month table shows production, self-use, imports, credited exports and both bills.
Typical values for Malaysia
| Item | Typical range |
|---|---|
| Specific yield (Klang Valley, Penang, Johor) | 1,100–1,300 kWh/kWp per year |
| Installed price, home systems (2026 quotes) | RM3,000–4,000 per kWp |
| Self-consumption without a battery | 30–60% of production |
| Payback, well-sized home system | 5–8 years |
| Panel degradation | 0.4–0.7% per year |
Tips to get the best return
- Size the system to your daytime use, not to your whole bill. Exports are worth roughly 40% less than self-used solar.
- In Malaysia’s near-equatorial latitude, roof orientation matters little: east and west roofs lose only a few percent compared with south. Avoid shading above all.
- Ask installers for the AC (inverter) rating as well as the panel kWp, and check it is within the 5 or 15 kWac limit.
- Shift flexible loads into the 10 am–4 pm window.
- Compare at least three quotes from SEDA-registered installers.
Limitations
The household load shape is typical, not yours; if you have smart-meter data, adjust the “extra daytime use” setting until the self-consumption share looks right. We assume the export credit is applied after taxes and levies; the guideline does not spell out how credits interact with KWTBB and SST. Solar ATAP rules apply to TNB customers in Peninsular Malaysia only; Sabah and Sarawak have separate arrangements. The 25-year cash flow applies the same savings rate after the 10-year contract, which slightly flatters systems that export a lot. Installed prices come from installer quotes, not an official survey. See the Malaysian solar page for the wider picture, the general solar panel calculator for other countries, and the TNB bill calculator to check your bill.
Method & assumptions
For each hour of the chosen year we simulate the PV output from NASA POWER irradiance and temperature (sun position, Hay–Davies sky model, cell temperature, inverter clipping at the Solar ATAP AC limit). Household demand is spread over the day with a typical Malaysian load shape (Malaysia is UTC+8). Solar used at the same hour as demand is self-consumption; the rest is export.
Each month the TNB bill without solar is compared with the bill for the remaining grid imports, minus the export credit: exported kWh up to the smaller of the imports and the maximum allowable quantity (kWac × 5 h × days), valued at the energy charge rate (27.03 sen/kWh, or 37.03 sen/kWh above 1,500 kWh) and limited to the energy charge of that bill. Payback, NPV and IRR come from a 25-year cash flow with degradation, tariff growth, maintenance and an inverter replacement in year 12.
Frequently asked questions
What is Solar ATAP?
How are solar exports credited under Solar ATAP?
How big a solar system can I install on my house under Solar ATAP?
How much does rooftop solar cost in Malaysia?
What is the payback period for solar in Malaysia?
How much electricity does a 6 kWp system produce in Kuala Lumpur?
Sources & references
- Energy Commission — Guidelines for Solar Accelerated Transition Action Programme (Solar ATAP) in Peninsular Malaysia, GP/ST/No. 60/2025 (via SEDA)
- pv magazine — Malaysia introduces rooftop solar scheme to replace net metering (9 January 2026)
- NASA POWER — hourly solar and meteorological data
- Single Buyer — System Marginal Price for NEM NOVA and Solar ATAP
Embed this calculator
Free for blogs, installers, schools and NGOs. Copy the code below; it updates itself automatically.