Malaysia calculator

Aircond BTU calculator: what horsepower your room needs and what it costs to run

Enter your room size to get the right aircond capacity in BTU/h and HP (1.0, 1.5, 2.0 or 2.5 HP), then see the kWh and the real extra amount on your TNB bill for running it every night.

Editable share link Branded PDF report Free · no sign-up

Results

A 1.0 HP (9,000 BTU/h) unit suits this room (calculated load 7,200 BTU/h). Running it 8 hours a day adds about RM 51 a month to your bill.
Recommended size
1.0 HP (9,000 BTU/h)
calculated load 7,200 BTU/h
Extra on your bill per month
50.92RM
55.7 sen per extra kWh at your usage
Electricity per month
91kWh
Per night / day of use
1.7RM
3 kWh per day
Average power draw
381W
rated cooling 2.64 kW
Per year
611RM
Monthly cost by hours of use (RM)

Inverter vs non-inverter for this room

TypekWh per monthRM per monthRM per year
Inverter9150.92611
Non-inverter13777.19926

Aircond size guide (normal room, 2.7 m ceiling)

SizeBTU/hRoom area (m²)Room area (sq ft)
1.0 HP9,0000–160–170
1.5 HP12,00016–21170–227
2.0 HP18,00021–32227–340
2.5 HP24,00032–42340–453
3.0 HP28,00042–49453–529
  • Cost is the difference between your monthly bill with and without this aircond, using the TNB tariff checked on 2026-11-14, so it includes tier, rebate and tax effects.
  • Sizing uses about 600 BTU/h per m² of floor for a room with a 2.7 m ceiling, adjusted for sun, roof exposure, people and heat sources. Rooms with poor insulation or large glass areas may need one size up.
  • Setting the thermostat to 24–25 °C instead of 20 °C typically cuts consumption by roughly a fifth to a third.

How this calculator works

Air-conditioning is the single biggest item on most Malaysian electricity bills. This tool answers the two questions people ask before buying one: which size do I need, and what will it cost me every month?

It first estimates the room’s cooling load in BTU per hour from the floor area, ceiling height, sun exposure, roof exposure, the number of people and any heat sources such as cooking. It then picks the smallest standard unit sold in Malaysia that covers the load: 1.0, 1.5, 2.0, 2.5 or 3.0 HP. Finally it converts that unit’s cooling output into electricity using its efficiency and a typical average load, and prices the extra kWh with the real TNB, SESB or Sarawak Energy domestic tariff.

The formula

Load (BTU/h) = area (m²) × 600 × (ceiling height ÷ 2.7) × sun factor × 1.15 if under the roof, + 600 per person above two, + 4,000 for a kitchen Average power (kW) = unit cooling capacity (kW) × average load ÷ efficiency (CSPF or EER) kWh per month = average power × hours per day × days Monthly cost = TNB bill (household + aircond) − TNB bill (household only)

The 600 BTU/h per m² figure is a hot-humid-climate rule that matches the sizes Malaysian retailers recommend (1.0 HP for a typical 3 × 4 m bedroom). 1 kW of cooling is 3,412 BTU/h.

The cost is a difference between two complete bills, not kWh × a flat rate. That matters with the July 2025 TNB tariff, because extra kWh can push you into a lower Energy Efficiency Incentive band or over the protection threshold, where AFA, the retail charge and SST kick in.

Worked example

The default is a 12 m² bedroom (3 × 4 m) with a normal amount of sun, two people and a 2.7 m ceiling:

  • Load: 12 × 600 = 7,200 BTU/h, so a 1.0 HP (9,000 BTU/h) unit is enough.
  • 9,000 BTU/h is 2.64 kW of cooling. At an average 65% load and an efficiency of 4.5, the unit draws about 380 W.
  • Eight hours a night for 30 nights: 0.38 × 8 × 30 ≈ 91 kWh a month.
  • The rest of the household uses 350 kWh. The TNB bill for 350 kWh versus 441 kWh differs by about RM51 a month, or roughly RM1.70 a night. That works out at 56 sen per extra kWh, well above the 27 sen energy charge, because the household drops from the 21 sen to the 14.5 sen EEI band.

How to read the results

  • Recommended size is the nominal capacity to look for on the box or the energy label.
  • Extra on your bill is what the aircond adds to your monthly bill at your current usage. The same unit costs more in a household that already uses a lot of power.
  • Average power draw is the realistic figure, far below the rated input power printed on the unit, because an inverter compressor runs at part load most of the night.
  • The inverter vs non-inverter table repeats the calculation with an efficiency of 4.5 and 3.0.

Typical sizes

Size Cooling (BTU/h) Cooling (kW) Typical room
1.0 HP 9,000 2.6 Bedroom up to about 15 m²
1.5 HP 12,000 3.5 Master bedroom, 15–21 m²
2.0 HP 18,000 5.3 Small living room, 21–31 m²
2.5 HP 24,000 7.0 Living and dining, 31–42 m²
3.0 HP 28,000 8.2 Open-plan areas up to about 49 m²

Tips to cut aircond costs

  • Set 24–25 °C and use the ceiling fan; avoid “turbo” at 16–18 °C.
  • Clean filters every few weeks and service the unit at least once a year; clogged coils lower efficiency noticeably.
  • Close curtains on west-facing windows in the afternoon and insulate the roof space if you live on the top floor.
  • Choose a unit with a high star rating on the Energy Commission label and an inverter compressor.
  • Run the timer so the unit switches off in the early morning when outdoor temperatures drop.
  • If you have rooftop solar, pre-cooling the house in the late afternoon uses your own solar power; see the Solar ATAP calculator.

Limitations

The sizing rule assumes a normally built Malaysian room. Rooms with large glass walls, poor insulation, many appliances or open doors need more capacity; a professional heat-load survey is better for big or unusual spaces. Average load and efficiency vary with model, outdoor temperature and thermostat setting, so treat the running cost as an estimate within about ±25%. Use the TNB bill calculator to see your whole bill, or the general air conditioner cost calculator for other countries.

Method & assumptions

Sizing: load (BTU/h) = floor area × 600 × (ceiling height ÷ 2.7) × sun factor (0.9 shaded, 1.0 normal, 1.15 sunny), × 1.15 under a roof, + 600 BTU/h per person above two, + 4,000 BTU/h for a kitchen. We pick the smallest standard unit (9,000 / 12,000 / 18,000 / 24,000 / 28,000 BTU/h, sold as 1.0 / 1.5 / 2.0 / 2.5 / 3.0 HP) that covers 95% of the load.

Energy: average electrical power = rated cooling (kW) × average load ÷ efficiency (CSPF or EER). kWh = power × hours × days. Cost: the bill for your household usage plus the aircond minus the bill without it, with the current TNB, SESB or Sarawak Energy domestic tariff.

Frequently asked questions

What size aircond do I need for my room in Malaysia?
As a rule of thumb, about 600 BTU/h per square metre of floor for a normal room with a 2.7 m ceiling. That makes 1.0 HP (9,000 BTU/h) right for a bedroom up to about 15 m² (160 sq ft), 1.5 HP (12,000 BTU/h) up to about 21 m², 2.0 HP (18,000 BTU/h) up to about 31 m² and 2.5 HP (24,000 BTU/h) up to about 42 m². Size up one step for west-facing rooms, top floors or kitchens.
How many BTU is 1 HP aircond?
In Malaysian shops 1.0 HP means a unit with about 9,000 BTU/h (2.6 kW) of cooling, 1.5 HP about 12,000 BTU/h (3.5 kW), 2.0 HP about 18,000 BTU/h (5.3 kW) and 2.5 HP about 24,000 BTU/h (7 kW). The 'HP' is a trade label, not the compressor's mechanical horsepower.
How much does it cost to run a 1 HP aircond for 8 hours?
A 1.0 HP inverter unit at 24–25 °C typically uses 2.5 to 3.5 kWh in an 8-hour night, so roughly 75 to 105 kWh a month. On a TNB bill that adds around RM45 to RM67 a month for a household already using 350 kWh, because the extra kWh also lower your Energy Efficiency Incentive rebate.
Is an inverter aircond worth it?
Usually yes if you use it most nights. An inverter unit slows its compressor down instead of switching on and off, and good models reach a seasonal efficiency (CSPF) of 5 or more against about 3 for a basic non-inverter unit. That cuts running costs by a third or more, which typically repays the price difference within two to four years of nightly use.
What temperature should I set my aircond to save electricity?
24 to 25 °C is the usual recommendation in Malaysia. Each degree higher saves very roughly 5 to 10% of the aircond's consumption. Using a ceiling fan at the same time lets you feel comfortable at a higher setting.
Is a bigger aircond better?
No. An oversized unit cools the air quickly and then stops, so it removes less moisture and the room feels clammy, and non-inverter units cycle more. Choose the size that matches the heat load and buy the most efficient model you can.

Sources & references

  1. Energy Commission (Suruhanjaya Tenaga) — energy efficiency labelling of electrical equipment
  2. U.S. Department of Energy — Room air conditioners: sizing and efficiency
  3. IEA — The Future of Cooling
  4. TNB — Pricing & tariffs (residential)

Embed this calculator

Free for blogs, installers, schools and NGOs. Copy the code below; it updates itself automatically.