Results

Each MWh discharged costs 170 $ over the project life: 104.4 for capital, 19 for O&M and 46.5 for charging energy (including losses). The system must earn about 130 $/MWh more than it pays for charging power. At an average selling price of 140 $/MWh it does not cover its costs.
LCOS
170$/MWh
0.17 $ per kWh
Capital share
104.4$/MWh
O&M share
19$/MWh
Charging share
46.5$/MWh
86% round trip
Required spread
130$/MWh
selling minus charging price
Energy capacity
400MWh
Installed cost
100million $
Discharged in year 1
118,800MWh
Capacity at end of life
72%
LCOS breakdown ($/MWh)
LCOS vs cycles per year

Yearly operation

YearCapacityMWh dischargedO&M ($)Charging cost ($)
1100%118,8002,000,0005,525,581
298%116,4242,000,0005,415,070
396%114,0482,000,0005,304,558
494%111,6722,000,0005,194,047
592%109,2962,000,0005,083,535
690%106,9202,000,0004,973,023
788%104,5442,000,0004,862,512
886%102,1682,000,0004,752,000
984%99,7922,000,0004,641,488
1082%97,4162,000,0004,530,977
1180%95,0402,000,0004,420,465
1278%92,6642,000,0004,309,953
1376%90,2882,000,0004,199,442
1474%87,9122,000,0004,088,930
1572%85,5362,000,0003,978,419
  • Linear capacity fade, no augmentation or cell replacement; real projects often add modules to hold capacity. Calendar ageing at low cycling is not modelled separately.
  • LCOS is pre-tax and in real terms; it excludes grid connection fees, capacity payments and ancillary service revenues. Battery prices have fallen fast; enter a current quote.

Free calculator by Energy.co.my