Results

A net efficiency of 55% (LHV) equals a heat rate of 6,874 Btu/kWh HHV or 6,545 kJ/kWh LHV. Each MWh needs 6.55 GJ of fuel, about 190 m³ (Natural gas), costing 52.4 € and emitting 0.367 t CO₂.
Heat rate (HHV)
6,874Btu/kWh
6,204 Btu/kWh on an LHV basis
Net efficiency (LHV)
55%
Net efficiency (HHV)
49.6%
Heat rate (LHV)
6,545kJ/kWh
1,563 kcal/kWh
Fuel energy per MWh (LHV)
6.55GJ/MWh
6.87 MMBtu/MWh HHV
Fuel per MWh (Natural gas)
190m³
Fuel cost per MWh
52.4€/MWh
CO₂ per MWh
0.367t
367 g/kWh
Annual generation
1,927GWh
Annual fuel use
365.6million m³
12.61 PJ of fuel
Annual fuel + carbon cost
101million €
Annual CO₂
0.71Mt
Heat rate vs efficiency (LHV)
Typical net efficiency by technology (LHV)

Heat rate in every unit

UnitLHV basisHHV basis
Btu/kWh6,2046,874
kJ/kWh6,5457,252
kcal/kWh1,5631,732
GJ/MWh6.5457.252
MMBtu/MWh6.2046.874

Typical technologies

TechnologyEfficiency (LHV)Heat rate (kJ/kWh, LHV)Heat rate (Btu/kWh, LHV)
Old subcritical coal33%10,90910,340
Supercritical coal39%9,2318,749
Ultra-supercritical coal44%8,1827,755
Lignite (modern)40%9,0008,530
Gas engine / recip44%8,1827,755
Aeroderivative OCGT40%9,0008,530
Heavy-duty OCGT37%9,7309,222
CCGT (F-class)57%6,3165,986
CCGT (H/J-class)62%5,8065,503
Oil steam plant36%10,0009,478
Diesel genset38%9,4748,979
Biomass steam30%12,00011,374
Nuclear LWR33%10,90910,340
  • Heat rate = 3,600 kJ/kWh ÷ efficiency = 3,412 Btu/kWh ÷ efficiency. HHV/LHV conversion uses typical fuel ratios (gas 1.108, bituminous coal 1.045, lignite 1.09, oil 1.06).
  • Fuel calorific values and CO₂ factors are IPCC 2006 defaults; your fuel analysis will differ, especially for coal and lignite.

Free calculator by Energy.co.my