Results

At 80% load and 25 °C the unit delivers 343.8 MW and burns 2,375 MMBtu of gas per hour (64,920 m³/h). Part-load efficiency is 54.7% LHV (heat rate 6,909 Btu/kWh HHV), so fuel costs 55.3 € per MWh.
Gas consumption
2,375MMBtu/h
2,506 GJ/h (HHV)
Volume flow
64,920m³/h
55.02 million scf per day
Mass flow
50.6t/h
Electrical output
343.8MW
available at 25 °C: 429.8 MW
Efficiency at this point (LHV)
54.7%
Heat rate (HHV)
6,909Btu/kWh
6,578 kJ/kWh LHV
Fuel cost per MWh
55.3€/MWh
CO₂ per MWh
367kg
Annual gas use
11.88million MMBtu
0.325 billion m³ · 11.46 Bcf
Annual generation
1,719GWh
Annual fuel + carbon cost
95million €
Annual CO₂
630kt
Gas flow and efficiency vs load
Output vs ambient temperature

Part-load table

LoadOutput (MW)Efficiency (LHV)Heat rate (Btu/kWh HHV)MMBtu/hm³/h€/MWh
30%128.944%8,5851,10730,25468.7
40%171.947.8%7,9151,36137,18763.3
50%214.950.3%7,5121,61444,12160.1
60%257.952.2%7,2441,86851,05458
70%300.853.6%7,0522,12257,98756.4
80%343.854.7%6,9092,37564,92055.3
90%386.855.6%6,7972,62971,85454.4
100%429.856.4%6,7072,88278,78753.7
  • Part-load and ambient corrections are generic curves for screening. Manufacturer correction curves (output, heat rate vs load, temperature, humidity, altitude) give exact values.
  • CO₂ factor 53.06 kg/MMBtu HHV (US EPA). Gas density assumed 0.78 kg/m³; m³ at 15 °C, 1 atm.

Free calculator by Energy.co.my