Results

Going from 78% to about 92% efficiency with better controls cuts fuel use by 20%, saving 365 € a year. The boiler pays back in 9.6 years; over 15 years you come out 2,820 € ahead.
Saving per year
€365
20% less fuel
Payback
9.6 years
Net gain over 15 years
€2,820
with 2% a year fuel price growth
Fuel saved per year
3,655kWh
from 18,000 to 14,345 kWh
Old boiler efficiency
78%
New boiler efficiency
92%
at 55 °C flow
CO₂ saved per year
738kg
Useful heat (unchanged)
14,040kWh/yr
Cumulative net saving
Yearly saving by flow temperature
  • Condensing boilers recover heat from the water vapour in the flue gas, but only when the return water is cooler than the dew point (about 55 °C for natural gas, 47–48 °C for oil). Many are installed and left at 75–80 °C flow, where they work like a good non-condensing boiler.
  • Efficiencies are seasonal net values typical of field trials, a few points below lab ratings. Lowering the flow temperature on an existing condensing boiler, often to 50–55 °C, is a free saving worth trying before replacing anything.

Free calculator by Energy.co.my