A 1.0 HP (9,000 BTU/h) unit suits this room (calculated load 7,200 BTU/h). Running it 8 hours a day adds about RM 51 a month to your bill.
Recommended size
1.0 HP (9,000 BTU/h)
calculated load 7,200 BTU/h
Extra on your bill per month
50.92RM
55.7 sen per extra kWh at your usage
Electricity per month
91kWh
Per night / day of use
1.7RM
3 kWh per day
Average power draw
381W
rated cooling 2.64 kW
Per year
611RM
Inverter vs non-inverter for this room
| Type | kWh per month | RM per month | RM per year |
|---|---|---|---|
| Inverter | 91 | 50.92 | 611 |
| Non-inverter | 137 | 77.19 | 926 |
Aircond size guide (normal room, 2.7 m ceiling)
| Size | BTU/h | Room area (m²) | Room area (sq ft) |
|---|---|---|---|
| 1.0 HP | 9,000 | 0–16 | 0–170 |
| 1.5 HP | 12,000 | 16–21 | 170–227 |
| 2.0 HP | 18,000 | 21–32 | 227–340 |
| 2.5 HP | 24,000 | 32–42 | 340–453 |
| 3.0 HP | 28,000 | 42–49 | 453–529 |
- Cost is the difference between your monthly bill with and without this aircond, using the TNB tariff checked on 2026-11-14, so it includes tier, rebate and tax effects.
- Sizing uses about 600 BTU/h per m² of floor for a room with a 2.7 m ceiling, adjusted for sun, roof exposure, people and heat sources. Rooms with poor insulation or large glass areas may need one size up.
- Setting the thermostat to 24–25 °C instead of 20 °C typically cuts consumption by roughly a fifth to a third.